2-WIRE CLOCK IC

Results: 2,154

Photo
Mft.Part#
Specification
Price(USD)
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 3.77 PSI ~ 18.27 PSI (26 kPa ~ 126 kPa)
 Output Type: IC, SPI
 Output: 24 b

--

LPS22HBTR Datasheet

In Stock: 1000

RFQ

 Series: NPA-300
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 1 PSI (6.89 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 5 PSI (34.47 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 5 PSI (34.47 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 1 PSI (6.89 kPa)
 Output Type: Analog Voltage

--


 Series: MPXV7002
 Part Status: Active
 Pressure Type: Compound
 Operating Pressure: 0.29 PSI (2 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 0.073 PSI (0.5 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-500
 Part Status: Obsolete
 Pressure Type: Vented Gauge
 Operating Pressure: 0.73 PSI (5 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Obsolete
 Pressure Type: Vented Gauge
 Operating Pressure: 0.73 PSI (5 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-500
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 0.073 PSI (0.5 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-500
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 0.073 PSI (0.5 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 0.073 PSI (0.5 kPa)
 Output Type: Analog Voltage

--


 Series: MP3V5050
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 7.25 PSI (50 kPa)
 Output Type: Analog Voltage

--


 Series: MP3V5004
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 0.57 PSI (3.92 kPa)
 Output Type: Analog Voltage

--


 Series: MPXV5050
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 7.25 PSI (50 kPa)
 Output Type: Analog Voltage

--


 Series: NPC-120, NovaSensor
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: -0.97 PSI ~ 5.8 PSI (-6.67 kPa ~ 40 kPa)
 Output Type: Wheatstone Bridge

--

NPC-120T Datasheet

In Stock: 9600

RFQ

 Series: NPC-100, NovaSensor
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: -0.97 PSI ~ 5.8 PSI (-6.67 kPa ~ 40 kPa)
 Output Type: Wheatstone Bridge

--

NPC-100T Datasheet

In Stock: 1000

RFQ

 Series: NPA-100
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 0.36 PSI (2.49 kPa)
 Output Type: Wheatstone Bridge

--


 Series: NPA-100
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 5 PSI (34.47 kPa)
 Output Type: Wheatstone Bridge

--


 Series: SCP1000
 Part Status: Obsolete
 Pressure Type: Absolute
 Operating Pressure: 4.35 PSI ~ 17.4 PSI (30 kPa ~ 120 kPa)
 Output Type: SPI

--


 Series: NPA-500
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Analog Voltage

--


 Series: NPA-100
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Wheatstone Bridge

--


 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 203.05 PSI (1400 kPa)
 Output Type: Digital
 Output: 16 b

--


 Series: SDP3x
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: -0.07 PSI ~ 0.07 PSI (-0.5 kPa ~ 0.5 kPa)
 Output Type: Analog Voltage

--


 Series: MPR
 Part Status: Active
 Pressure Type: Gauge
 Operating Pressure: 1 PSI (6.89 kPa)
 Output Type: SPI

--


 Series: MPXM2053
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 7.25 PSI (50 kPa)
 Output Type: Wheatstone Bridge

--


 Series: NPA-500
 Part Status: Obsolete
 Pressure Type: Vented Gauge
 Operating Pressure: 0.18 PSI (1.25 kPa)
 Output Type: Analog Voltage

--


 Series: NPP-301
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Wheatstone Bridge

--


 Series: NPA-100
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: Wheatstone Bridge

--


 Series: NPA-600
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 1 PSI (6.89 kPa)
 Output Type: ZACwire

--


 Series: MPXM2102
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 14.5 PSI (100 kPa)
 Output Type: Wheatstone Bridge

--


 Series: MPR
 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 15 PSI (103.42 kPa)
 Output Type: SPI

--


 Series: NPA-600
 Part Status: Active
 Pressure Type: Differential
 Operating Pressure: 5 PSI (34.47 kPa)
 Output Type: ZACwire

--


 Series: NPA-300
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 0.18 PSI (1.25 kPa)
 Output Type: Analog Voltage

--


 Series: MPR
 Part Status: Obsolete
 Pressure Type: Gauge
 Operating Pressure: 5.8 PSI (40 kPa)
 Output Type: SPI

--


 Series: NPA-100
 Part Status: Active
 Pressure Type: Vented Gauge
 Operating Pressure: 5 PSI (34.47 kPa)
 Output Type: Wheatstone Bridge

--


 Part Status: Active
 Pressure Type: Absolute
 Operating Pressure: 2.18 PSI ~ 16.68 PSI (15 kPa ~ 115 kPa)
 Output Type: Analog Voltage
 Output: 0.12 V ~ 2.8 V

--


Hot Searches

Categories
Top