CABLE

Results: 5,038

Photo
Mft.Part#
Specification
Price(USD)
 Series: W4S-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 7.087" (4mm ~ 180mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4-3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 15.748" ~ 137.795" (400mm ~ 3.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 19.685" (500mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 24 ~ 240VAC, 12 ~ 240VDC
 Response Time: 20ms, 30ms

--

PMP6RG Datasheet

In Stock: 1000

RFQ

 Series: W4S-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 4.724" (4mm ~ 120mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: WLL180T
 Part Status: Active
 Sensing Method: Fiber Optic
 Sensing Distance: 787.402" (20m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W12-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.181" ~ 19.685" (30mm ~ 500mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: LS-500
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 98.425" (100mm ~ 2.5m) 0.033' ~ 8.202'
 Voltage - Supply: 12 V ~ 24 V

--

LS-H901 Datasheet

In Stock: 1000

RFQ

 Series: W4-3 PTFE
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 4.724" (4mm ~ 120mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PowerProx
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.969" ~ 149.606" (50mm ~ 3.8m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4SLG-3V
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 78.740" (2m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PowerProx
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.969" ~ 98.425" (50mm ~ 2.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4-3 PTFE
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 98.425" (2.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CY
 Part Status: Obsolete
 Sensing Method: Retroreflective
 Sensing Distance: 5.9" (15cm)
 Voltage - Supply: 10 V ~ 30 V

--

CY-29 Datasheet

In Stock: 1000

RFQ

 Series: W27-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.181" ~ 78.740" (30mm ~ 2m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: EX-30
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 1.969" (50mm)
 Voltage - Supply: 12 V ~ 24 V

--

EX-32A Datasheet

In Stock: 44

RFQ

 Series: CY-100
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 32.80' (10m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 16.40' (5m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: EX-Z
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 19.685" (500mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: EX-20
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 1.77" ~ 5.906" (45mm ~ 150mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Voltage - Supply: 12 V ~ 24 V
 Response Time: 1ms

--


 Part Status: Active
 Sensing Method: Cross-beam
 Sensing Distance: 3.937" (100mm)
 Voltage - Supply: 12 V ~ 24 V
 Response Time: 10ms

--


 Part Status: Active
 Sensing Distance: 0.197" ~ 6.102" (5mm ~ 155mm)
 Voltage - Supply: 10 V ~ 30 V
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable
 Connection Method: Cable with Connector, M12, 4POS

--


 Series: G10
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.150" ~ 590.551" (80mm ~ 15m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: MOF
 Part Status: Active
 Sensing Method: Through-Beam
 Voltage - Supply: 8V
 Connection Method: Cable

--

MOFR Datasheet

In Stock: 5

RFQ

 Series: LD
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 5.906" (150mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PM2
 Part Status: Active
 Sensing Method: Reflective, Convergent
 Sensing Distance: 0.197" (5mm)
 Voltage - Supply: 5 V ~ 24 V

--


 Series: PD
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 236.22" (6m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PD
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 236.22" (6m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: G10
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 11.81" ~ 374.02" (300mm ~ 9.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: Z-Sensor
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 188.976" (100mm ~ 4.8m)
 Voltage - Supply: 10 V ~ 30 V

--

ZL3-N2415 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 7.874" (200mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.4" (20m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 10ms, 20ms

--


 Series: Z-Sensor
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 188.976" (100mm ~ 4.8m)
 Voltage - Supply: 10 V ~ 30 V

--

ZL1-N2277 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 3.5ms, 6.5ms

--


 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 3.5ms, 6.5ms

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 16.40' (5m)
 Voltage - Supply: 12 V ~ 24 V

--


 Part Status: Active
 Sensing Method: Retroreflective, Polarized
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.402" (20m)
 Voltage - Supply: 10 V ~ 30 V

--


Categories
Top