CABLE

Results: 5,038

Photo
Mft.Part#
Specification
Price(USD)
 Series: E3Z
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 3.543" (90mm)
 Voltage - Supply: 12 V ~ 24 V

--

E3Z-L81 Datasheet

In Stock: 1000

RFQ

 Series: W4-3 Glass
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.394" (10mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3ZM
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.394" ~ 3.937" (10mm ~ 100mm) ADJ
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3ZM
 Part Status: Active
 Sensing Method: Transmissive
 Sensing Distance: 0.591" (15mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W9-3
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 275.591" (7m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.181" ~ 11.811" (30mm ~ 300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3Z
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 3.543" (90mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W9-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.787" ~ 19.685" (20mm ~ 500mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3Z
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 15m
 Voltage - Supply: 12 V ~ 24 V

--


 Series: E3S-A
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 275.591" (7m)
 Voltage - Supply: 12 V ~ 24 V

--

E3S-AT41 Datasheet

In Stock: 1000

RFQ

 Series: KT3
 Part Status: Active
 Sensing Distance: 0.492" (12.5mm)
 Voltage - Supply: 12 V ~ 24 V
 Response Time: 50s

--


 Series: W4S-3 Inox
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 4.724" (4mm ~ 120mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4S-3 Inox
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 11.024" (4mm ~ 280mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: KT5
 Part Status: Active
 Sensing Distance: 0.787" (20mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 50s

--


 Series: W12-2 Laser
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 3149.606" (80m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3L
 Part Status: Obsolete
 Sensing Method: Through-Beam
 Sensing Distance: 393.701" (10m)
 Voltage - Supply: 12 V ~ 24 V

--

E3L-2DC4 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 2.362" (60mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 230V
 Response Time: 50ms, 40ms

--


 Series: E3F2
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 275.591" (7m)
 Voltage - Supply: 10 V ~ 30 V

--

E3F2-7C4 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 118.110" (100mm ~ 3m)
 Voltage - Supply: 10 V ~ 30 V
 Output Configuration: NPN - Dark-ON/Light-ON - Selectable

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 433.071" (100mm ~ 11m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Part Status: Active
 Sensing Distance: 3.937" ~ 149.606" (100mm ~ 3.8m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 5ms
 Output Configuration: NPN/PNP - Light-ON

--


 Series: W16
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.39" ~ 19.69" (10mm ~ 500mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CY-100
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: CY-100
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 3.937" (100mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: E3FA
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 39.37" (1m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PH
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 39.370" (1m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: Z-Sensor
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 2.362" (5mm ~ 60mm)
 Voltage - Supply: 10 V ~ 30 V

--

ZT2-P2228 Datasheet

In Stock: 1000

RFQ

 Series: Z-Sensor
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 6.102" (5mm ~ 155mm)
 Voltage - Supply: 10 V ~ 30 V

--

ZT2-N5238 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 39.370" (1m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1ms

--


 Series: E3C
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 39.370" (1m)
 Connection Method: Cable

--

E3C-1D 5M Datasheet

In Stock: 1000

RFQ

 Series: ELF4
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 2.362" (5mm ~ 60mm)
 Voltage - Supply: 10 V ~ 30 V

--

ET4-P2238 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 629.921" (16m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1ms

--


 Series: GR18S
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 21.654" (5mm ~ 550mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 16.40' (5m)
 Voltage - Supply: 12 V ~ 24 V

--


 Part Status: Active
 Sensing Method: Retroreflective, Polarized
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Part Status: Active
 Sensing Method: Retroreflective, Polarized
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 23.622" (5mm ~ 600mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 11.811" (5mm ~ 300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 590.551" (15m)
 Voltage - Supply: 10 V ~ 30 V

--


Categories
Top