CABLE

Results: 5,038

Photo
Mft.Part#
Specification
Price(USD)
 Series: W27-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.181" ~ 62.992" (30mm ~ 1.6m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3S-A
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 275.591" (7m)
 Voltage - Supply: 12 V ~ 24 V

--

E3S-AT91 Datasheet

In Stock: 1000

RFQ

 Series: W27-2
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 3.937" ~ 39.370" (100mm ~ 1m)
 Voltage - Supply: 24 V ~ 240 V

--


 Series: E3C
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 1.181" ~ 39.370" (30mm ~ 1m) ADJ
 Connection Method: Cable

--


 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 5.906" (150mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 330s, 660s

--


 Series: E3L
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 393.701" (10m)
 Voltage - Supply: 12 V ~ 24 V

--

E3L-2LRC4 Datasheet

In Stock: 1000

RFQ

 Series: CX-400
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 3.937" (100mm)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: E3RA
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 11.811" (300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3Z
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 0.787" ~ 7.874" (20mm ~ 200mm) ADJ
 Voltage - Supply: 12 V ~ 24 V

--


 Series: E3FB
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 3.937" ~ 78.740" (100mm ~ 2m) ADJ
 Voltage - Supply: 10 V ~ 30 V

--


 Part Status: Active
 Sensing Distance: 0.394" ~ 15.748" (10mm ~ 400mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1ms
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 118.110" (100mm ~ 3m)
 Voltage - Supply: 10 V ~ 30 V
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable

--


 Part Status: Active
 Sensing Distance: 0.197" ~ 5.906" (5mm ~ 150mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s
 Output Configuration: NPN/PNP - Light-ON

--


 Part Status: Active
 Sensing Distance: 0.787" ~ 13.780" (20mm ~ 350mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 330s
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable

--


 Part Status: Active
 Sensing Distance: 3.937" ~ 78.740" (100mm ~ 2m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1.5ms
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable

--


 Part Status: Active
 Sensing Distance: 3.937" ~ 62.992" (100mm ~ 1.6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1.5ms
 Output Configuration: PNP - Dark-ON/Light-ON - Selectable

--


 Series: W16
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0" ~ 196.850" (0m ~ 5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W26
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 0' ~ 196.90' (0 ~ 60m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: GR18S
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 21.654" (5mm ~ 550mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: ELF3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 6.102" (5mm ~ 155mm)
 Voltage - Supply: 10 V ~ 30 V

--

ET3-F5228 Datasheet

In Stock: 1000

RFQ

 Series: ELF3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.039" ~ 3.937" (1mm ~ 100mm)
 Voltage - Supply: 10 V ~ 30 V

--

ET3-P4238 Datasheet

In Stock: 1000

RFQ

 Series: ELF4
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 1.969" (50mm)
 Voltage - Supply: 10 V ~ 30 V

--

ET4-P3228 Datasheet

In Stock: 1000

RFQ

 Series: ELF3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.394" (10mm)
 Voltage - Supply: 10 V ~ 30 V

--

EL3-F2828 Datasheet

In Stock: 1000

RFQ

 Series: E3FA
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 39.37" (1m)
 Voltage - Supply: 10 V ~ 30 V

--

E3FA-DP26 Datasheet

In Stock: 1000

RFQ

 Series: GR18S
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.118" ~ 4.528" (3mm ~ 115mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 16.40' (5m)
 Voltage - Supply: 12 V ~ 24 V

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Series: CX-400
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 16.40' (5m)
 Voltage - Supply: 12 V ~ 24 V

--

CX-493-J Datasheet

In Stock: 1000

RFQ

 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 1.181" ~ 255.906" (30mm ~ 6.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 1.181" ~ 255.906" (30mm ~ 6.5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 984.252" (25m)
 Voltage - Supply: 10 V ~ 30 V

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 15" (4.57m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1ms

--

RCDC0000 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.4" (20m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 1ms

--


 Series: W9-3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 15.748" (400mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3Z
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 39.370" (1m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W9-3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 15.748" (400mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4S-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.394" ~ 7.087" (10mm ~ 180mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3S
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 196.850" (5m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W4S-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 4.724" (4mm ~ 120mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W9-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.787" ~ 19.685" (20mm ~ 500mm)
 Voltage - Supply: 10 V ~ 30 V

--


Categories
Top