 Series: FX-500
 Part Status: Active
 Sensing Method: Reflective, Convergent
 Sensing Distance: 0.118" ~ 0.551" (3mm ~ 14mm) ADJ
 Connection Method: Cable

--


 Series: W16
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.39" ~ 19.69" (10mm ~ 500mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W16
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.39" ~ 29.53" (10mm ~ 750mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: ISD400
 Part Status: Active
 Voltage - Supply: 18 V ~ 30 V
 Connection Method: Connector, M12
 Ingress Protection: IP65

--


 Series: EX-L200
 Part Status: Active
 Sensing Method: Reflective, Convergent
 Sensing Distance: 0.787" ~ 2.756" (20mm ~ 70mm) ADJ
 Voltage - Supply: 12 V ~ 24 V

--


 Series: PH
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.402" (20m)
 Voltage - Supply: 10 V ~ 30 V

--

PH18CNT20 Datasheet

In Stock: 1000

RFQ

 Series: PH
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.402" (20m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PD
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 39.370" (1m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: PD
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 39.370" (1m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: Photologic
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 0.080" ~ 0.220" (2.03mm ~ 5.58mm) ADJ
 Voltage - Supply: 4.75 V ~ 5.25 V

--

OPB760T Datasheet

In Stock: 1000

RFQ

 Series: ELF4
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 188.976" (100mm ~ 4.8m)
 Voltage - Supply: 10 V ~ 30 V

--

EL4-P2415 Datasheet

In Stock: 1000

RFQ

 Series: Z-Sensor
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 188.976" (100mm ~ 4.8m)
 Voltage - Supply: 10 V ~ 30 V

--

ZL1-E2277 Datasheet

In Stock: 1000

RFQ

 Series: GR18S
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 1.181" ~ 283.465" (30mm ~ 7.2m)
 Voltage - Supply: 10 V ~ 30 V

--


 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 236.2" (6m)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Series: GR18
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.118" ~ 4.528" (3mm ~ 115mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: CY-100
 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 4.724" (120mm)
 Voltage - Supply: 24 ~ 240 VAC

--

CY-12B-J Datasheet

In Stock: 1000

RFQ

 Series: G6
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.236" (6mm)
 Voltage - Supply: 10 V ~ 30 V

--

GL6-N4212 Datasheet

In Stock: 1000

RFQ

 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 23.622" (5mm ~ 600mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Part Status: Active
 Sensing Method: Reflective, Diffuse
 Sensing Distance: 7.874" (200mm)
 Voltage - Supply: 10 V ~ 30 V
 Response Time: 500s

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 1.181" ~ 255.906" (30mm ~ 6.5m)
 Voltage - Supply: 21.6 V ~ 250 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 1.181" ~ 255.906" (30mm ~ 6.5m)
 Voltage - Supply: 21.6 V ~ 250 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 11.811" (5mm ~ 300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: GR18S
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.118" ~ 11.811" (3mm ~ 300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.197" ~ 11.811" (5mm ~ 300mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 787.402" (20m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: G10
 Part Status: Active
 Sensing Method: Through-Beam
 Sensing Distance: 1574.803" (40m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W2S-2
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.039" ~ 1.417" (1mm ~ 36mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 118.110" (100mm ~ 3m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W2 Flat
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.079" ~ 0.709" (2mm ~ 18mm)
 Voltage - Supply: 12 V ~ 24 V

--

WT2F-P140 Datasheet

In Stock: 1000

RFQ

 Series: E3T
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.394" ~ 3.937" (10mm ~ 100mm) ADJ
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W4S-3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 157.480" (4m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4S-3
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 196.850" (5m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: E3Z
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 157.480" (4m)
 Voltage - Supply: 12 V ~ 24 V

--


 Series: W4-3 Glass
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 0.039" ~ 157.480" (1mm ~ 4m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: W4-3
 Part Status: Active
 Sensing Method: Proximity
 Sensing Distance: 0.157" ~ 5.906" (4mm ~ 150mm)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: EQ-30
 Part Status: Active
 Sensing Method: Reflective
 Sensing Distance: 78.7" (2m) 6.6'
 Voltage - Supply: 10 V ~ 30 V

--

EQ-34-C5 Datasheet

In Stock: 1000

RFQ

 Part Status: Active
 Sensing Method: Retroreflective, Polarized
 Sensing Distance: 472" (12m) 39.4'
 Voltage - Supply: 10.8 V ~ 264 V
 Response Time: 20ms, 30ms

--

PMP12RG Datasheet

In Stock: 1000

RFQ

 Series: SureSense
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 3.937" ~ 472.441" (100mm ~ 12m)
 Voltage - Supply: 10 V ~ 30 V

--


 Series: MQ-W
 Part Status: Last Time Buy
 Sensing Method: Reflective
 Sensing Distance: 27.559" (700mm)
 Voltage - Supply: 9.6 V ~ 30 V

--


 Series: W4S-3 Inox
 Part Status: Active
 Sensing Method: Retroreflective
 Sensing Distance: 157.480" (4m)
 Voltage - Supply: 10 V ~ 30 V

--